• <s id="hmc8x"><sub id="hmc8x"><option id="hmc8x"></option></sub></s>
    1. <label id="hmc8x"></label>
    <s id="hmc8x"></s>

    Chinese | EngishNational Service Hotline:+86-0592-5919855
    Product
    Contact

    Xiamen Kelungde Env. Engineering Co., Ltd.

    Contacts:Ms.Wu

    Tel:+86 0592- 5919855/5915855

    QQ:819135252

    MB:+86 13806020340

    E-mail:kelungde@163.com    wakerobin@163.com

    KLD Mono&Multiple Water Quality Analyzer
    On-line Analyzer for Ammonia and Phosphate Monitoring

    On-line Analyzer for Ammonia and Phosphate Monitoring

        KLD-C-NH3-N & PO4 is an automatic on-line analyzer independently developed by KLD. Using imported CPU, highly precise signal processor and simple but steady loop flow system to effectively reduce signal fluctuation and to ensure the accuracy and stability of data. Complete separation between electronics and hydraulics allows long-term & stable running. It is suitable for several types of water matrix like river water, surface water and industrial effluent.



    Hits:176
    Product Presentation

        KLD-C-NH3-N & PO4 is an automatic on-line analyzer independently developed by KLD. Using imported CPU, highly precise signal processor and simple but steady loop flow system to effectively reduce signal fluctuation and to ensure the accuracy and stability of data. Complete separation between electronics and hydraulics allows long-term & stable running. It is suitable for several types of water matrix like river water, surface water and industrial effluent.


    Features

    1.      Robust & Reliable

    Designed for on-line industrial and environmental applications. Complete separation between electronics and hydraulics allows long-term stable operations.

    2.      Precise Reagent Dosage

    CPU controlled photoelectric dosing system for accurate reagent dosage. Simple & steady structure ensures long-term service life.

    3.      Easy Installation

    Delivered after a long & successful series of factory tests, it is ready for installation and setup. To start monitoring just need to connect reagent tubes, sample tube, water tube, waste tube and power supply, then set up the parameters.

    4.      Automatic Calibration

    The analyzer performs calibration according to the calibration interval and type set up by users. If the result exceeds selected limits, the original calibration parameters will not be updated and an alarm signal will be outputted.

    5.      Automatic Monitoring

    Measuring interval can be freely set up by users. Between two measurements the analyzer remains in standby.


    Benefits

    ?  Automatic monitoring system gives alarm signal in abnormal condition. Easy and low maintenance; Low operating cost.

    ?  4-20mA analog signal output; standard RS232, RS485 digital signal output, MODBUS protocol.

    ?  New signal processor reduces signal fluctuation to ensure the accuracy and stability of data.

    ?  Highly precise peristaltic pump extends the service life of pump tubes.

    ?  Automatic restart when normal power supply after accidental power down.

    ?  Remote control with local or remote PC connection.

    ?  Low reagent consumption; short preparation time.

    ?  Automatic diagnosis function. Identification and alarm for reagent shortage.

    ?  Instrument operating signal output function.

    ?  3000 groups of data storage and USB download for analysis data and running log.

    ?  Easy operation, no special training is required.

    ?  Controllable running of water pump and free setup for the sampling time of the pump.

    ?  Security management function, automatic record and storage for all control operations. Read-only storage.

    ?  2-level operation & management authorization: The system administrator can have all system operation and general operators can only perform routine maintenance & operation.


    Measuring Principle

    NH3-N: The sample after proper filtration is pumped into the reactor, where R1(phenol, sodium nitroprusside, potassium tartrate and potassium hydroxide) and R2 (sodium dichloro isocyanurate) are injected and heated to 50°C. Sample reacts with phenol, potassium tartrate and sodium dichloro isocyanurate under alkaline conditions (using sodium nitroprusside as a catalyst ). After fully mixing and reaction, the analyzer measures ABS value of blue substances produced by reaction at the specific wavelength, then calculates sample concentration according to the stored calibration data.

    PO4: The sample after proper filtration is pumped into the reactor, where molybdate is injected to form phosphorus-molybdenum heteropoly acid. Then, injecting ascorbic acid into the sample. After fully mixing and reaction, the analyzer measures ABS value of blue substances produced by reaction at the specific wavelength, then calculates sample concentration according to the stored calibration data.


    Specifications

    Measuring Principle

    NH3-N

    PO4

    Colorimetric, Phenate Method

    Colorimetric, Molybdate Ascorbic Acid Method

    Operating Management

    Security management and 2-Level operation management function

    Measuring Type

    Manual or automatic with interval

    Measuring Interval

    Programmable; reverse control available by RS232

    Measuring Time

    12 minutes

    5 minutes

    Measuring Range

    0.01~0.5/5/20/50mg/L, other ranges available on request

    Calibration Type

    Manual or automatic analysis at specified intervals

    Precision

    ≤ 5%

    Zero Drift

    5%F.S

    Accuracy

    ±5%

    Range Drift

    5%F.S

    Signal Output

    Standard 4-20mA analog output, Standard RS232/RS485 digital   output, MODBUS Protocol

    Alarm

    High limit alarm, low limit alarm, reagent shortage alarm,   calibration error alarm (standard)

    Sample and Waste Delivery

    Pressure free

    Reagent Temperature

    10-30°C

    Reagent Replacement

    3~4 weeks (depending on the ambient temperature)

    Ambient temperature

    5-40°C

    Protection

    IP55

    MTBF

    720h

    Display

    Color touch screen (language: Chinese Simplified, Chinese   Traditional, English)

    Power supply

    220V AC±10%; power 90W

    Weight

    60kg (without reagents)

    Dimension

    1600×500×400mm(H×W×D) (with the height of base)


    Optional Functions

    Dual-channel

    One analyzer to monitor on-line for 2 outlets.

    Reagent Cooling

    Longer reagent service life and less reagent replacing.

    Alarm Function

    DI water low limit alarm and waste liquid high limit alarm function.

    Automatic Dilution Function

    Automatic dilution function for high concentration sample.

    Mini Printer

    Print data after measurement.


      Tags:On-line Analyzer for Ammonia and Phosphate Monitoring
      Home | About | Job | Contact | Guess
      日本成a人片在线观看网址,www日韩中文字幕在线看,亚洲第一成人影院,亚洲欧美日韩一区高清中文字幕 鹰潭市| 钟山县| 太湖县| 剑阁县| 高密市| 嵊州市| 康马县| 洞头县| 蓝山县| 德令哈市| 班戈县| 平原县| 栖霞市| 奇台县| 洪泽县| 拜城县| 兴山县| 陕西省| 汕尾市| 电白县| 罗甸县| 东源县| 横峰县| 高碑店市| 太和县| 太谷县| 元江| 资兴市| 武清区| 泰安市| 休宁县| 山西省| 伊吾县| 水城县| 海安县| 正安县| 廊坊市| 简阳市| 光泽县| 建瓯市| 武胜县| http://444 http://444 http://444 http://444 http://444 http://444